M102 (Heat Pump Control Unit): Difference between revisions
Jump to navigation
Jump to search
GeorgeDewar (talk | contribs) No edit summary |
GeorgeDewar (talk | contribs) No edit summary |
||
| Line 4: | Line 4: | ||
| Connector No. || M102 | | Connector No. || M102 | ||
|- | |- | ||
| Connector Name || | | Connector Name || [[Heat Pump Control Unit]] | ||
|- | |- | ||
| Connector Type || TH16FW-NH | | Connector Type || TH16FW-NH | ||
Revision as of 12:35, 28 April 2025
| Connector No. | M102 |
| Connector Name | Heat Pump Control Unit |
| Connector Type | TH16FW-NH |
| Connector Color | WHITE |
Pinout
| Pin No. | Color of Wire | Signal Name |
|---|---|---|
| 1 | Lavender / Brown |
HP LIN |
| 2 | Lavender / Violet |
TD SENS |
| 3 | - | - |
| 4 | - | - |
| 5 | - | - |
| 6 | Lavender / Light Green |
2WAY VALVE |
| 7 | Lavender / White |
3WAY VALVE |
| 8 | Black |
SENS GND |
| 9 | Lavender / Green |
+B |
| 10 | - | - |
| 11 | Lavender / Yellow |
TS SENS |
| 12 | - | - |
| 13 | - | - |
| 14 | - | - |
| 15 | - | - |
| 16 | Black |
GND |