B24 (Li-Ion Battery): Difference between revisions
Jump to navigation
Jump to search
GeorgeDewar (talk | contribs) No edit summary |
GeorgeDewar (talk | contribs) m GeorgeDewar moved page B24 (LI-ION BATTERY) to B24 (Li-Ion Battery) |
||
(2 intermediate revisions by the same user not shown) | |||
Line 4: | Line 4: | ||
| Connector No. || B24 | | Connector No. || B24 | ||
|- | |- | ||
| Connector Name || | | Connector Name || [[Li-Ion Battery]] | ||
|- | |- | ||
| Connector Type || RH36FG-GY | | Connector Type || RH36FG-GY | ||
|- | |- | ||
| Connector Color || | | Connector Color || Green | ||
|} | |} | ||
Line 24: | Line 24: | ||
| 3 || - || - | | 3 || - || - | ||
|- | |- | ||
| 4 || {{WireColor|R}} || | | 4 || {{WireColor|R}} || Power On Power Supply | ||
|- | |- | ||
| 5 || {{WireColor|SB}} || 12V | | 5 || {{WireColor|SB}} || 12V Battery Power Supply | ||
|- | |- | ||
| 6 || {{WireColor|B}} || | | 6 || {{WireColor|B}} || Ground | ||
|- | |- | ||
| 7 || {{WireColor|B}} || | | 7 || {{WireColor|B}} || Ground | ||
|- | |- | ||
| 8 || {{WireColor|B}} || | | 8 || {{WireColor|B}} || Ground | ||
|- | |- | ||
| 9 || - || - | | 9 || - || - | ||
|- | |- | ||
| 10 || {{WireColor|B}} || | | 10 || {{WireColor|B}} || Pre-Charge Relay Ground | ||
|- | |- | ||
| 11 || {{WireColor|G}} || | | 11 || {{WireColor|G}} || Pre-Charge Relay Input | ||
|- | |- | ||
| 12 || - || - | | 12 || - || - | ||
|- | |- | ||
| 13 || {{WireColor|B}} || | | 13 || {{WireColor|B}} || System Main Relay 2 Ground | ||
|- | |- | ||
| 14 || {{WireColor|L}} || | | 14 || {{WireColor|L}} || System Main Relay 2 Input | ||
|- | |- | ||
| 15 || - || - | | 15 || - || - | ||
|- | |- | ||
| 16 || {{WireColor|B}} || | | 16 || {{WireColor|B}} || System Main Relay 1 Ground | ||
|- | |- | ||
| 17 || {{WireColor|Y}} || | | 17 || {{WireColor|Y}} || System Main Relay 1 Input | ||
|- | |- | ||
| 18 || - || - | | 18 || - || - | ||
Line 78: | Line 78: | ||
| 30 || - || - | | 30 || - || - | ||
|- | |- | ||
| 31 || {{WireColor|P}} || | | 31 || {{WireColor|P}} || Charging Activation Signal | ||
|- | |- | ||
| 32 || - || - | | 32 || - || - |
Latest revision as of 12:15, 2 May 2025
Connector No. | B24 |
Connector Name | Li-Ion Battery |
Connector Type | RH36FG-GY |
Connector Color | Green |
Pinout[edit | edit source]
Pin No. | Color of Wire | Signal Name |
---|---|---|
1 | Blue |
CAN-H |
2 | Green |
CAN-L |
3 | - | - |
4 | Red |
Power On Power Supply |
5 | Sky Blue |
12V Battery Power Supply |
6 | Black |
Ground |
7 | Black |
Ground |
8 | Black |
Ground |
9 | - | - |
10 | Black |
Pre-Charge Relay Ground |
11 | Green |
Pre-Charge Relay Input |
12 | - | - |
13 | Black |
System Main Relay 2 Ground |
14 | Blue |
System Main Relay 2 Input |
15 | - | - |
16 | Black |
System Main Relay 1 Ground |
17 | Yellow |
System Main Relay 1 Input |
18 | - | - |
19 | - | - |
20 | - | - |
21 | - | - |
22 | - | - |
23 | - | - |
24 | - | - |
25 | - | - |
26 | - | - |
27 | - | - |
28 | - | - |
29 | - | - |
30 | - | - |
31 | Pink |
Charging Activation Signal |
32 | - | - |
33 | - | - |
34 | - | - |
35 | - | - |
36 | - | - |